• Small Silent Biogas Electric Generator for Biogas Plant
  • Small Silent Biogas Electric Generator for Biogas Plant
  • Small Silent Biogas Electric Generator for Biogas Plant
  • Small Silent Biogas Electric Generator for Biogas Plant
  • Small Silent Biogas Electric Generator for Biogas Plant

Small Silent Biogas Electric Generator for Biogas Plant

Output Type: AC Three Phase
Gas Source: Biogas
Certification: CE, ISO, CCC
Power: >200kW
Standard: Standard
Power Usage: Daily Usage, Industrial Usage, Sell to Grid
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Controller
Comap, Deepsea
Ignition System
Altronic
Lube Oil
Total Gas Engine Oil 15W-40
Voltage
400/230V
Lubrication Mode
Pressure and Splash
Installation Service
Available Abroad
Spare Parts
Factory OEM
Alternator
Siemens: Brushless, with AVR, Insula
Transport Package
Plywood Case with Plastic Film Inside
Specification
Composition: CH4
Origin
China
Production Capacity
5000sets/Year

Product Description


 Scope of Application

        Waste to electricity, by farm waste biogas project, industry water waste biogas project, landfil project to get the biogas and realize the electricity generation.
 
Advantage

--Advanced configuration keep accurate ans stable working condition under high speed working speed
--High generalization, easy maintenance, low maintenance cost.
--Economical, low operating cost
--Reduced the carbon deposition on the wear of the engine cylinder and the valve to prolong the using life of the genset.
--Adopt one of the world's most advanced gas control technology, fully available to the characteristics of fuel gas.
--Powerful low pressure gas SPI (single point Injection) system used for various supercharger premixed engine.
--Suitable for differnt concentration methane and propane, variety of quality gas.
--Precise air-fuel ratio rarefied combustion control and Generator speed/load control
--Realize lean burn, reduce the intake pipe tempering and improved efficient to reduce the heat load.

 Requirements For Biogas Gas Genset Working Condition

Within 1m from pressure regulating valve of gas intake

Gas temperature ≤ 40º C
Pressure 3-20kpa, pressure changing rate ≤ 1kpa/min
H2S ≤ 200mg/Nm3
NH3 ≤ 20mg/Nm3
CH4 content ≥ 40%, changing rate ≤ 2%min
Impurity particle size ≤ 5μ M, impurity content ≤ 30mg/Nm3
Moisture content ≤ 40g/Nm3

High Configuration

--Ignition system: ALTRONIC(USA)
--Starting system: DC24V electric motor. 
--Mixer: IMPCO(USA)  
--Sparking plug:STITT
--Engine Control System: Woodward(USA), HEINZMANN(Germany)
--Electric Control System: ComAp(Czech), Deepsea(UK)
--Alternator: Siemens, LEROY-SOMER, Marathon  

Certificate
We have CE, ISO14001, ISO9001 and CEC certificate to keep the good quality. Please contact us for more details. 
 
Service 

1.Pre-sale service:
A.Our engineers are available for onsite prospect before installation free to charge. 
B. Foundation drawing and detailed Dimension free form us.
 
2.In-sale service:
A. Onsite overall guide installation,operation and maintenance training . 
B. Assistance and instruction of trial running. 
 
3.After-sale service: 
A. 24 hours online or in person after sale service. 
B.12 months warranty. We take care of all errors/breakdowns in this period. 
 
4.Spare parts service: 
A.All spares parts on our gensets supplied by us. 
B. Free spare parts together with genset when shipping. 

Accessories

1) Application scope of the Accessories, such as 12v190, 8v190, 6190, 6135 and other engine types. 
2.)All parts were from original factories or professional factories, complete in specification, keep good quality. 
 
Sincerely welcome to visit our factory and build future cooperation relationship.

Biogas generator list
Gen-set mode Prime power Continuous power Engine Mode Displacement 
LHBG10 10kw 8kw LH2100 1.80L 
LHBG20 20kw 16kw LH4100 3.61L
LHBG30 30kw 24kw LH4105 4.32L
LHBG40 40kw 32kw LH6105 6.45L
LHBG50 50kw 40kw LH4135 8.58L
LHBG60 60kw 48kw LH4135 8.58L
LHBG70 70kw 56kw LH6135 12.8L
LHBG80 80kw 64kw LH6135 12.8L
LHBG90 90kw 72kw LH6135 12.8L
LHBG100 100kw 80kw LH6135 12.8L
LHBG120 120kw 100kw LH12V135 25.75L
LHBG150 150kw 120kw LH12V135 25.75L
LHBG180 180kw 144kw LH12V135 25.75L
LHBG200 200kw 160kw LH12V135 25.75L
LHBG300 300kw 240kw LH6190 35.70L
LHBG400 400kw 320kw LH12V190 71.45L
LHBG500 500kw  400kw LH12V190 71.45L
Parameter of biogas generator 
Rate Voltage 400V/230V
Phase 3Phase  4 wires
Rate Frequency 50HZ/60HZ
Power Factor 0.8
Voltage Regulating Range 95%-105%
Voltage Steady State ≤±2%
Voltage Transient State ≤±10%
Voltage Settling ≤1S
Voltage Volatility ≤±0.5%
Frequency Steady State Regulation Rate ≤0.5%
Frequency Transient State  Regulation Rate ≤±10%
Heat Consumption 10mj/kw.h
Pressure 5-20kpa
Intake Mode Natural intake
Sparking Mode Sparking plug
Voltage Regulation Mode automatic
Speed Regulation Mode Electronic speed regulation
Lubricating Mode Pressure and splash
Cooling Mode Closed/open circulating water cooling
Starting Mode 24V electric motor
Overhaul Time ≥30000h
Noise ≤105aB(A)
Exhaust Temperature ≤650°C


FAQ

1)How to choose the right model?
 
Firstly, depending on the loading equipment or the total power you need.
Secondly, depending on the hours the genset working per day.
Thirdly, depending on the LHV of the fuel gas. 
 
Please consult us and we will recommend you the most suitable modell for your need. 
 
2) What kind of gas could generate electricity?
 
We use the internal combustion engine. And the suitable gas are natural gas, biogas, syngas and LPG.
 
If the fuel gas is not the natural gas, please contact us and we will recommend you the suitable model based on the LHV of the fuel gas. And we will provide our professional suggestions.
 
3) What will be the electricity used for?
 
Please kindly tell us the electricity will be used for the loading equipment or for the grid. We will recommend the suitable model for the loading equipment and the suitable configuration for the grid.
 
4) Voltage and frequency required.
 
Necessary information could be supplied. Our standard configuration is 220/380V and 50/60HZ. Please contact us for other voltage and frequency. We will make the suitable proposal
 
5) What is the consumption of the genset?
 
This will be based on the LHV of the fuel gas. Please contact us and we will provide you the exact data. 
 
6) Warranty 
 
1Year not including the quick-wear parts. But we could provide you some free parts with the genset.  

Small Silent Biogas Electric Generator for Biogas Plant

Small Silent Biogas Electric Generator for Biogas Plant
 

Small Silent Biogas Electric Generator for Biogas Plant

 




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now