Output Type: AC Three Phase
Gas Source: Biogas
Certification: CE, ISO, CCC
Power: >200kW
Standard: Standard
Power Usage: Daily Usage, Industrial Usage, Sell to Grid
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Controller
Comap, Deepsea
Ignition System
Altronic
Lube Oil
Total Gas Engine Oil 15W-40
Voltage
400/230V
Lubrication Mode
Pressure and Splash
Installation Service
Available Abroad
Spare Parts
Factory OEM
Alternator
Siemens: Brushless, with AVR, Insula
Transport Package
Plywood Case with Plastic Film Inside
Specification
Composition: CH4
Origin
China
Production Capacity
5000sets/Year

Product Description

High Efficient Stanford AlternatorCE approved 100 - 150 kw biogas generator refuse landfill

Core Features:
Manufacturer supply
Power supply range:10kw - 1000kw
Continuous supply range: 8kw -1000kw
Standard component and assembly
Multi-option of control panel
With CE and ISO certificate
Natural gas generator specification: 
Power factor:  0.8
Rated Voltage and Rated Frequency:  400V/230V, 50/60HZ
Voltage Stabilized Regulation:  ≤ ± 1.5%
Frequency Fluctuation Ratio:  ≤ ± 1%
Insulation Class:  H
Fuel: natural gas, CNG,LNG,methane.  biogas , biomass gas, coal bed gass, coal oven gas,coal gas

gas generator parameter:
 

 Biogas generator list
 Genset Mode  Prime power  Continuous power  Engine Mode  Displacement 
 LHBG10  10kw  8kw  LH2100  1.80L 
 LHBG20  20kw  16kw   LH4100  3.61L
 LHBG30  30kw   24KW  LH4105  4.32L
 LHBG40  40KW  32KW  LH6105  6.45L
 LHBG50  50KW  40KW  LH4135  8.58L
 LHBG60  60KW  48KW  LH4135  8.58L
 LHBG70  70KW  56KW  LH6135  12.8L
 LHBG80  80KW   64KW  LH6135  12.8L
 LHBG90  90KW  72KW  LH6135  12.8L
 LHBG100  100KW  80KW  LH6135  12.8L
 LHBG120  120KW  96KW   LH12V135  25.75L
 LHBG140  140KW  115KW   LH12V135  25.76L
 LHBG150  150KW  120KW  LH12V135  25.75L
 LHBG180  180KW  144KW  LH12V135  25.75L
 LHBG200  200KW  160KW  LH12V135  25.75L
 LHBG250  250KW  200KW  LH12V190  35.75L
 LHBG300  300KW  240KW   LH12V190  35.75L
 LHBG350  350KW  280KW  LH12V190  35.75L
 LHBG400  400KW  320KW  LH12V190  71.45L
 LHBG500  500KW  400KW  LH12V190  71.45L
 LHBG600  600KW  480KW  LH12V190  71.45L
 Parameter of biogas generator 
 Rate Voltage  400V/230V
 Phase  3Phase  4 wires
 Rate Frequency  50HZ/60HZ
 Power Factor  0.8
 Voltage Regulating Range  95%-105%
 Voltage Steady State  ≤±2%
 Voltage Transient State  ≤±10%
 Voltage Settling  ≤1S
 Voltage Volatility  ≤±0.5%
Frequency Steady State Regulation Rate  ≤0.5%
 Frequency Transient State  Regulation Rate  ≤±10%
 Heat Consumption  9.8mj/kw.h
 Pressure  5-20kpa
 Intake Mode  Natural intake
 Sparking Mode  Sparking plug
 Voltage Regulation Mode  automatic
 Speed Regulation Mode  Electronic speed regulation
 Lubricating Mode  Pressure and splash
 Cooling Mode  Closed/open circulating water cooling
 Starting Mode  24V electric motor
 Overhaul Time  ≥20000h
 Noise  ≤105aB(A)
 Exhaust Temperature  ≤650°C



(Single set power supply range: 10 - 1000 kw, ≥2 sets parallel together to form large power, Eg. 600kw*2 sets = 1200 kw)
 
Machine supply details:
Ignition system:We adopt ignition system of magneto which produced by American ALTRONIC company,including:magneto,high-tension coil,sparking plug.
Starting system: DC24V electric motor,12v190 adopt ST710 of direct-current.
Pressure charging system:Pulse Mixed-flow  supercharger, compression ration is  1:8,meet engine's  requirement   for gas-flow rate.
Speed regulating system: EGS gas controller of American WOODWARD Company.   
Features of our generator:  
1.Pure copper water tank for best cooling effect 
2.Famous component brand to ensure overall quality, Eg. Siemens,Standard, Stanford.
3.Expansion fitting combined with shrinking fitting give high tightness to the system. 
4.Safety guarantee form electromagnetic valve as well as back-fire relief valve 
5.Residual heat CHP recycle system available for choice.
Industrial Generators Efficient Stanford Alternatorce Approved 100 - 150 Kw Biogas Generator Refuse Landfill

Our Services :
1.Pre-sale service:
A.Our engineers are available for onsite prospect before installation free to charge.
B. Foundation drawing and detailed Dimension free form us.

2.In-sale service:
A. Onsite overall guide installation,operation and maintenance training . 
B. Assistance and instruction of trial running. 

3.After-sale service: 
A.Our every engineers are in charge of different area,we will response periodically and support you 
technical service free of charge,
B.For the quality problem, we will service for you free of charge during the guarantee period.
C.One year guarantee period and lifetime service. 
D.we solve quality problem in time when genset doesn't work,We insure to help our clients to gain

4.Spare parts service: 
A.All spares parts on our gensets supplied by us. 
B. Free spare parts together with genset when shipping.

Industrial Generators Efficient Stanford Alternatorce Approved 100 - 150 Kw Biogas Generator Refuse Landfill

 

Industrial Generators Efficient Stanford Alternatorce Approved 100 - 150 Kw Biogas Generator Refuse Landfill

Industrial Generators Efficient Stanford Alternatorce Approved 100 - 150 Kw Biogas Generator Refuse Landfill
Industrial Generators Efficient Stanford Alternatorce Approved 100 - 150 Kw Biogas Generator Refuse Landfill
 




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now